Mitsubishi Electric PLK-G-PAL Technical Manual page 167

Industrial sewing machine
Table of Contents

Advertisement

< sequel to INPUT SIGNAL >
Code
SP0~SP9 Speed dial signal
Speed up signal
SPU
Speed down signal
SPD
Cassette jig sensor 1 signal
CK1
Cassette jig sensor 2 signal
CK2
Function
Speed dial value is switched to 0~9.
Speed dial value is increased +1.
Speed dial value is decreased -1.
When CK1 and CK2 inputs is on, OF1 output turn on.
*CK1 and CK2 is effective when [Cassette jig function ON/OFF(CHK)] and
[Cassette jig sensor ON/OFF(CSN)] has been sets to ON.
Specifications
[14] - 8