Mitsubishi Electric PLK-G-PAL Technical Manual page 176

Industrial sewing machine
Table of Contents

Advertisement

<Continuation of [Clamp]>
Function
3B
Clamp 3 of output off delay
setting
4B
Clamp 4 of output off delay
setting
5B
Clamp 5 of output off delay
setting
6B
Clamp 6 of output off delay
setting
7B
Clamp 7 of output off delay
setting
8B
Clamp 8 of output off delay
setting
OFB
The divisions of clamp
blocks
FN
Setting for valid number of
clamp
CF
Clamp synchronize
ON/OFF setting
F21N
Number of valid clamp with
clamp block setting
(OF1-OF4)
F22N
Number of valid clamp with
clamp block setting
(OF5-OF8)
CF1
Clamp synchronize setting
with clamp block
setting(OF1-OF4)
CF2
Clamp synchronize setting
with clamp block
setting(OF5-OF8)
F4BN
Setting for number of valid
clamp blocks
Unit
Setting range
ms
0 ~ 10000
ms
0 ~ 10000
ms
0 ~ 10000
ms
0 ~ 10000
ms
0 ~ 10000
ms
0 ~ 10000
8 clamps can be bundled to blocks.
-
NO
2
4
-
1 ~ 8
The [The divisions of clamp (OFB.)] is validated when set to [NO].
-
OF
ON
-
1 ~ 4
-
1 ~ 4
The [The divisions of clamp(OFB.)] is validated when set to [2].
(For details, see the timing chart.)
-
OF
ON
The [The divisions of clamp(OFB.)] is validated when set to [2].
(For details, see the timing chart.)
-
OF
ON
-
1 ~ 4
Sets the time (TB3) from the clamp input 3 ON
to clamp output 3 OFF.
Sets the time (TB4) from the clamp input 4 ON
to clamp output 4 OFF.
Sets the time (TB5) from the clamp input 5 ON
to clamp output 5 OFF.
Sets the time (TB6) from the clamp input 6 ON
to clamp output 6 OFF.
Sets the time (TB7) from the clamp input 7 ON
to clamp output 7 OFF.
Sets the time (TB8) from the clamp input 8 ON
to clamp output 8 OFF.
Use 8 clamp types in 1 block (OF1-OF8). The following functions
become valid: [Setting of valid clamp(FN.)] and [Setting of clamp
link (CF.)].
Use 8 clamps in 2 blocks (OF1-OF4)(OF5-OF8). The following
functions become valid: (F21N.) (F22N.) (CF1.) (CF2.).
Use 8 clamp types in 4 blocks (OF1,OF2), (OF3,OF4),
(OF5,OF6), (OF7,OF8). The following functions become valid:
[No. of valid clamp blocks setting(F4BN.)] and [No. of block steps
used setting(F4SN.)]
[Divisions of clamp (OFB.)] is validated when set to [NO].
Number of outputs (clamp) from [PR1(OF1)] to [PR8(OF8)] can
be set. Sewing is possible when all selected number of outputs
(clamp) are [ON].
The clamps are not synchronized.
The clamps are synchronized. (For details, see the timing chart.)
Setting is effective when OFB=[2].
1:Use clamp output OF1.
2:Use clamp output OF1+OF2.
3:Use clamp output OF1+OF2+OF3.
4:Use clamp output OF1+OF2+OF3+OF4.
Setting is effective when OFB=[2].
1:Use clamp output OF5.
2:Use clamp output OF5+OF6.
3:Use clamp output OF5+OF6+OF7.
4:Use clamp output OF5+OF6+OF7+OF8.
Clamps (OF1-OF4) will not link.
Clamps (OF1-OF4) will link.
Clamps (OF5-OF8) will not link.
Clamps (OF5-OF8) will link.
Setting is effective when OFB=[4]. Following blocks are used
depends on the setting.
1:Block1,
2:Block1+2,
3:Block1+2+3,
4:Block1+2+3+4.
(Block1=OF1+OF2, Block2=OF3+OF4, Block3=OF5+OF6,
Block4=OF7+OF8)
[16] - 3
Specification

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents