Clear

The gray [Clear]'s primary function is to delete cues and tracks and clear
submasters . You can also delete channel tracks using [Clear] . Occasion-
ally an error message may prompt you to press [Clear].
You can also use [Clear] to clear an incorrect level setting and reset it to
zero . To do so, select channels, and press [At] [Clear].
Deleting a cue, submaster or group
To delete a cue or clear a submaster, follow these steps:
1. Press [Blind] . You must be in Blind to delete cues or clear
submasters.
2 . Press [Cue], [Sub] or [Group] .
3 . Enter the cue, submaster or group number you want to delete. If
you are deleting a group, press [Enter] after you enter the group
number.
4 . Press [Clear] .
5 . Press [Record] to delete cue, submaster or group . Or, press [Cue],
[Sub] or [Group] to restore it.