Network operation
8.1 Network operation
Select the <Service network> softkey to obtain access to the network parameters input
screen.
Figure 8-1
Table 8-1
Parameter
DHCP
Computer name
IP address
Subnet mask
Enabling the communication ports
Use the <Service firewall> softkey to enable or disable communication ports.
To ensure maximum possible safety, all ports not needed should be closed.
8-2
Network parameters
Required network parameters
Explanation
DHCP log: A DHCP server is needed in the network which dynamically distrib-
utes the IP addresses.
When No is selected fixed network addresses will be assigned.
When Yes is selected the network addresses are assigned dynamically. Input
fields that are no longer needed will be hidden.
Name of the control system in the network
Network address of the control system (e.g. 192.168.1.1)
Network identification (e.g. 255.255.252.0)