Siemens SINUMERIK 802D sl Programming And Operating Manual page 195

Hide thumbs Also See for SINUMERIK 802D sl:
Table of Contents

Advertisement

All the G functions are displayed.
Use this softkey to display the "Axis feedrate" window.
Pressing the softkey repeatedly will close the window.
Use this softkey to switch from the seven-block to the three-block display.
Switches the axis value display between the machine, workpiece and relative coordinate
systems.
The program control softkeys are displayed (e.g. "Skip block", "Program test").
● <Program test>: If "Program test" is selected, the output of setpoints to axes and spindles
● <Dry run feedrate>: If you select this softkey, all traversing motions will be performed with
● <Conditional stop>: When this function is active, processing of the program is stopped at
● <Commenting out>: Program blocks, the block number of which is preceded by a slash,
● <Single block, fine>: If this function is active, the part program blocks are executed as fol-
● <ROV effective>: The feedrate override switch will also act on the rapid traverse override.
Use this softkey to close the screen.
Use the block search function to go to the desired program location.
Forward block search with calculation
During the block search, the same calculations are carried out as during normal program op-
eration, but the axes do not move.
Forward block search with calculation to the block end point
During the block search, the same calculations are carried out as during normal program op-
eration, but the axes do not move.
Block search without calculation
During the block search, no calculation is carried out.
Grinding
Programming and Operating manual, 06/2006, 6FC5398-4CP10-0BA0
is disabled. The set point display "simulates" the traverse movements.
the feedrate setpoint specified via the "Dry run feed" setting data. Instead of the pro-
grammed motion commands, the dry run feedrate will be effective.
every block in which miscellaneous function M01 is programmed.
are skipped during program execution (e.g. "/N100").
lows: Each block is decoded separately, and a stop is performed at each block; an excep-
tion are only the thread blocks without dry run feedrate. In such blocks, a stop is only per-
formed at the end of the current thread block. "Single Block fine" can only be selected in
the RESET status.