Chapter 1
General Troubleshooting
Test the Electrical Cabling
Replace the suspected bad cabling (the cables from the test set to the DSx panel or the EIA ports) with
Step 1
a known-good cable. For instructions, refer to the "Install Cards and Fiber-Optic Cable" chapter in the
Cisco ONS 15454 Procedure Guide.
If a known-good cable is not available, test the suspected bad cable with a test set. Remove the suspected
bad cable from the DSx panel or the EIA and connect the cable to the Tx and Rx terminals of the test
set. Run traffic to determine whether the cable is good or defective.
Step 2
Resend test traffic on the loopback circuit with a known-good cable installed. If the test set indicates a
good circuit, the problem was probably the defective cable.
Replace the defective cable.
Step 3
In card view for the electrical card, depending upon the type, click the Maintenance > Loopback tabs,
Step 4
Maintenance > DS1 tabs, or Maintenance > DS3 tabs.
Note
Choose None from the Loopback Type column for the port being tested.
Step 5
Choose the appropriate state (IS; OOS,DSBLD; OOS,MT; IS,AINS) from the Admin State column for
Step 6
the port being tested.
Click Apply.
Step 7
Click Yes in the confirmation dialog box.
Step 8
Complete the
Step 9
Test the Electrical Card
Complete the
Step 1
and replace it with a known-good one.
Resend test traffic on the loopback circuit with a known-good card installed.
Step 2
If the test set indicates a good circuit, the problem was probably the defective card. Return the defective
Step 3
card to Cisco through the Return Materials Authorization (RMA) process. Contact Cisco Technical
Support at 1 800 553-2447.
Complete the
Step 4
Step 5
In card view for the electrical card, depending upon the type, click the Maintenance > Loopback tabs,
Maintenance > DS1 tabs, or Maintenance > DS3 tabs.
Note
Choose None from the Loopback Type column for the port being tested.
Step 6
Choose the appropriate state (IS; OOS,DSBLD; OOS,MT; IS,AINS) from the Admin State column for
Step 7
the port being tested.
Click Apply.
Step 8
November 2009
The DS-3 Admin State is the basis of the DS-1 Derived State.
"Test the Electrical Card" procedure on page
"Physically Replace a Traffic Card" procedure on page 2-273
"Physically Replace a Traffic Card" procedure on page 2-273
The DS-3 Admin State is the basis of the DS-1 Derived State.
1.2.1 Perform a Facility Loopback on a Source Electrical Port (West to East)
1-13.
Cisco ONS 15454 Troubleshooting Guide, R8.5
for the suspected bad card
for the faulty card.
1-13