Alarm Troubleshooting
Clear the CONTBUS-B-18 Alarm
Complete the
Step 1
page 2-270
Wait approximately 10 minutes for the Slot 11 TCC2/TCC2P to reset as the standby TCC2/TCC2P.
Step 2
Verify that the ACT/SBY LED is correctly illuminated before proceeding to the next step. A green
ACT/SBY LED indicates an active card. An amber ACT/SBY LED indicates a standby card.
Position the cursor over the Slot 7 TCC2/TCC2P and complete the
Step 3
and Activate the Standby Card" procedure on page 2-270
state.
If the reset card has not rebooted successfully, or the alarm has not cleared, call Cisco TAC
Step 4
(1-800-553-2447). If the Cisco TAC technician tells you to reseat the card, complete the
Reinsert (Reseat) the Standby TCC2/TCC2P Card" procedure on page
technician tells you to remove the card and reinstall a new one, follow the
Card" procedure on page
2.7.65 CONTBUS-DISABLED
The CONTBUS-DISABLED alarm is a function of the enhanced cell bus verification feature. This alarm
occurs when a defective card is installed in the shelf assembly or when a card already installed in the
shelf assembly becomes defective (that is, the card fails the enhanced cell bus verification test). The
alarm persists as long as the defective card remains in the chassis. When the card is removed,
CONTBUS-DISABLED will remain raised for a one-minute wait time. This wait time is designed as a
guard period so that the system can distinguish this outage from a briefer card reset communication
outage.
If no card is reinserted into the original slot during the wait time, the alarm clears. After this time, a
different, nondefective card (not the original card) should be inserted.
When CONTBUS-DISABLED is raised, no message-oriented communication is allowed to or from this
slot to the TCC2/TCC2P (thus avoiding node communication failure).
CONTBUS-DISABLED clears only when the faulty card is removed for one minute. If any card at all is
Caution
reinserted before the one-minute guard period expires, the alarm does not clear.
CONTBUS-DISABLED overrides the
wait period, but afterward IMPROPRMVL can be raised because it is no longer suppressed.
IMPROPRMVL is raised after CONTBUS-DISABLED clears if the card is in the node database. If
CONTBUS-DISABLED has cleared but IMPROPRMVL is still active, inserting a card will clear the
IMPROPRMVL alarm.
November 2009
"Reset an Active TCC2/TCC2P Card and Activate the Standby Card" procedure on
to make the Slot 7 TCC2/TCC2P active.
2-273.
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
to return the Slot 11 TCC2/TCC2P to the active
"IMPROPRMVL" alarm on page 2-127
Cisco ONS 15454 Troubleshooting Guide, R8.5
2.7.65 CONTBUS-DISABLED
"Reset an Active TCC2/TCC2P Card
"Remove and
2-272. If the Cisco TAC
"Physically Replace a Traffic
during the one-minute
2-69