Cisco ONS 15454 Troubleshooting Manual page 395

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Chapter 2
Alarm Troubleshooting
The Equipment Power Failure at Connector B alarm occurs when there is no power supply from the main
power connector to the equipment. This alarm occurs on the electrical interface assemblies (EIA),
15454_MRC-12 Multirate card, MRC-2.5G-4 Multirate card, OC192SR1/STM64IO Short Reach and
OC192/STM64 Any Reach cards (also known as OC192-XFP in CTC), OC12 IR/STM4 SH 1310-4 card,
OC3 IR/STM1 SH 1310-8 card or TCC2/TCC2P.
The power supply circuitry for the equipment can constitute an energy hazard. Before you install or
Warning
replace the equipment, remove all jewelry (including rings, necklaces, and watches). Metal objects
can come into contact with exposed power supply wiring or circuitry inside the DSLAM equipment.
This could cause the metal objects to heat up and cause serious burns or weld the metal object to the
equipment. Statement 207
Clear the PWR-FAIL-B Alarm
Complete the
Step 1
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC 1 800 553-2447.
2.7.329 PWR-FAIL-RET-A
The Equipment Power Failure at Connector A alarm occurs when there is no power supplied to the
backup power connector on the shelf. This alarm occurs on the electrical interface assemblies (EIA),
15454_MRC-12 Multirate card, MRC-2.5G-4 Multirate card, OC192SR1/STM64IO Short Reach and
OC192/STM64 Any Reach cards (also known as OC192-XFP in CTC), OC12 IR/STM4 SH 1310-4 card,
OC3 IR/STM1 SH 1310-8 card or TCC2/TCC2P.
Clear the PWR-FAIL-RET-A Alarm
Complete the
Step 1
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 2
for more information or call Cisco TAC 1 800 553-2447.
2.7.330 PWR-FAIL-RET-B
November 2009
"Clear the PWR-FAIL-A Alarm" procedure on page
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
"Clear the PWR-FAIL-A Alarm" procedure on page
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: EQPT
2.7.329 PWR-FAIL-RET-A
2-200.
2-200.
Cisco ONS 15454 Troubleshooting Guide, R8.5
2-201

Advertisement