Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
WID-5006
Warning: A different secondary {0} node should only be used
for DRI or open-ended path protected circuits.
WID-5007
If you change the scope of this view, the contents of this profile
editor will be lost.
WID-5008
Please ensure that all the protection groups are in proper states
after the cancellation.
WID-5009
The circuit {0} is not upgradable.
No {1} capable {2}s are available at the node {3}.
EID-5010
The domain name already exists.
EID-5011
The domain name cannot exceed {0} characters.
WID-5012
The software load on {0} does not support the addition of a
node to a 1+1 protection group.
EID-5013
{0} does not support the bridge and roll feature. Please select a
different port.
EID-5014
An automatic network layout is already in progress.
Please wait for it to complete before running it again.
WID-5015
{0} cannot be applied to {1}.
EID-5016
An error occurred while attempting to provision the {0}.
{1}
EID-5017
Provisioning could not be rolled back. The {0} might be left in
an INCOMPLETE state and should be manually removed.
EID-5018
{0} is a(n) {1} node and cannot be added to a(n) {2} network. You cannot add the node {0} of type {1} to
EID-5019
The manual path trace mode for this equipment does not
support an expected string consisting of all null characters.
Please change the expected string or the path trace mode.
EID-5020
Software activation is in progress. Provisioning is not allowed. Refer to the warning message text.
EID-5021
Software activation is in progress. {0} is not allowed.
WID-5022
Warning: Ethergroup circuits are stateless (that is, always in
service).
The current state selection of {0} will be ignored.
EID-5023
CTC cannot communicate with the node.
The operation failed.
Cisco ONS 15454 Troubleshooting Guide, R8.5
4-34
Chapter 4
Description
You should use different secondary end
point only for DRI or open-ended path
protected circuits.
Refer to the warning message text.
Refer to the warning message text.
No VT capable STSs are available at the
node.
Refer to the error message text.
You may have reached the maximum
number of characters.
Refer to the warning message text.
The specified port does not support Bridge
and Roll.
You must for the automatic network layout
to complete before running it again.
You cannot apply the admin state operation,
specified by {0}, to port count, specified by
{1}.
CTC encountered an error while
provisioning the card.
You may have to remove the BLSR
manually as it was left incomplete.
the host node of type {2}. This prevents you
from hosting both SONET and SDH nodes
in the same session.
The path trace mode does not support
strings that consist of null characters. You
must either change the expected string or
the path trace mode.
Refer to the error message text.
Refer to the warning message text.
CTC encountered a network
communication error. Connectivity between
CTC and the NE was disrupted, either
transiently or permanently.
Error Messages