Table 2-18 Bic Compatibility Matrix - Cisco ONS 15454 Troubleshooting Manual

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

2.7.273 MEA (EQPT)
Clear the MEA (BIC) Alarm
Click the Provisioning > Inventory tabs to determine your backplane model. If the backplane is not a
Step 1
15454-SA-HD, replace the backplane or do not attempt to use high-density DS-3 cards.
the BICs that are compatible with various backplanes.
Table 2-18
BIC Type
BICs that work with the newer and older
backplanes
New HD BICs that work only with the new
backplanes
High-density BICs that work only with
15454-SA-HD
If you determine that your BIC type and backplane are compatible despite the MEA alarm, or if the alarm
Step 2
does not clear after you resolve the incompatibilities, log into the Technical Support Website at
http://www.cisco.com/techsupport for more information or call Cisco TAC 1 800 553-2447 in order to
report a Service-Affecting (SA) problem.
2.7.273 MEA (EQPT)
Cisco ONS 15454 Troubleshooting Guide, R8.5
2-182
BIC Compatibility Matrix
Default Severity: Critical (CR), Service-Affecting (SA)
SONET Logical Object: EQPT
Chapter 2
Part No.
MANUF_EQPT_ID_BIC_A_SMB_HD_BP
MANUF_EQPT_ID_BIC_B_SMB_HD_BP
MANUF_EQPT_ID_BIC_A_BNC_24_HD_BP
MANUF_EQPT_ID_BIC_A_BNC_48_HD_BP
MANUF_EQPT_ID_BIC_B_SMB
MANUF_EQPT_ID_BIC_B_SMB_ALT
MANUF_EQPT_ID_BIC_B_BNC_24
MANUF_EQPT_ID_BIC_B_BNC_48
MANUF_EQPT_ID_BIC_A_UNIV_VERT
MANUF_EQPT_ID_BIC_B_UNIV_VERT
MANUF_EQPT_ID_BIC_A_UNIV_HORIZ
MANUF_EQPT_ID_BIC_B_UNIV_HORIZ
MANUF_EQPT_ID_BIC_A_MINI_BNC_HD_BP
MANUF_EQPT_ID_BIC_B_MINI_BNC_HD_BP
MANUF_EQPT_ID_BIC_A_SMB
MANUF_EQPT_ID_BIC_A_SMB_ALT
MANUF_EQPT_ID_BIC_A_BNC_24
MANUF_EQPT_ID_BIC_A_BNC_48
Alarm Troubleshooting
Table 2-18
lists
November 2009