1.2.2 Perform a Hairpin Test on a Source-Node Electrical Port (West to East)
d.
e.
f.
g.
h.
i.
j.
k.
l.
Step 4
Confirm that the newly created circuit appears on the Circuits tab and that the Dir column describes it
as a one-way circuit.
Complete the
Step 5
Test and Delete the Electrical Port Hairpin Circuit
If the test set is not already sending traffic, send test traffic on the loopback circuit.
Step 1
Examine the test traffic received by the test set. Look for errors or any other signal information that the
Step 2
test set is capable of indicating.
If the test set indicates a good circuit, no further testing is necessary with the hairpin circuit. Clear the
Step 3
hairpin circuit:
a.
b.
c.
d.
e.
Complete the
Step 4
Test the Standby Cross-Connect Card
Two cross-connect cards (active and standby) must be in use on a node to use this procedure.
Note
Step 1
Perform a reset on the standby cross-connect card to make it the active card:
a.
Cisco ONS 15454 Troubleshooting Guide, R8.5
1-16
In the next Circuit Creation dialog box, give the circuit an easily identifiable name such as Hairpin1.
Choose the Size, such as STS-1.
Uncheck the Bidirectional check box. Leave the default values for State, SD Threshold, and
SF Threshold.
Click Next.
In the Circuit Creation source dialog box, select the same Node, card Slot, Port, and STS (or VT)
where the test set is connected. Leave Use Secondary Source unchecked.
Click Next.
In the Circuit Creation destination dialog box, use the same Node, card Slot, Port, and STS (or VT)
used for the source dialog box. Leave Use Secondary Destination unchecked.
Click Next.
In the Circuit Creation circuit routing preferences dialog box, leave all defaults. Click Finish.
"Test and Delete the Electrical Port Hairpin Circuit" procedure on page
Click the Circuits tab.
Choose the hairpin circuit being tested.
Click Delete.
Click Yes in the Delete Circuits dialog box. Do not check any check boxes.
Confirm that the hairpin circuit is deleted from the Circuits tab list.
"Test the Standby Cross-Connect Card" procedure on page
Determine the standby cross-connect card. On both the physical node and the CTC node view
window, the standby cross-connect ACT/SBY LED is amber and the active card ACT/SBY LED is
green.
Chapter 1
General Troubleshooting
1-16.