2.7.86 EOC
Clear the ENCAP-MISMATCH-P Alarm
Ensure that the correct framing mode is in use on the receive card:
Step 1
a.
b.
c.
Ensure that the correct framing mode is in use on the transmit card, and that it is identical to the receiving
Step 2
card:
a.
b.
c.
Step 3
If the alarm does not clear, use the CLI to ensure that the remaining settings are correctly configured on
the ML-Series or CE-1000 card:
To open the interface, click the IOS tab and click Open IOS Command Line Interface (CLI). Refer to
the Cisco ONS 15454 and Cisco ONS 15454 SDH Ethernet Card Software Feature and Configuration
Guide entries on all three of these topics to obtain the full configuration command sequences.
If the alarm does not clear, log into the Technical Support Website at http://www.cisco.com/techsupport
Step 4
for more information or call Cisco TAC 1 800 553-2447 in order to report a Service-Affecting (SA)
problem.
2.7.86 EOC
The SONET DCC Termination Failure alarm occurs when the ONS 15454 loses its DCC. Although this
alarm is primarily SONET, it can apply to DWDM. For example, the OSCM card can raise this alarm on
its OC-3 section overhead.
The SDCC consists of three bytes, D1 through D3, in the SONET overhead. The bytes convey
information about operation, administration, maintenance, and provisioning (OAM&P). The ONS 15454
uses the DCC on the SONET section layer to communicate network management information.
On the ONS 15454 OC-192 card, the laser is on when the card is booted and the safety key is in the on
Warning
position (labeled 1). The port does not have to be in service for the laser to be on. The laser is off when
the safety key is off (labeled 0). Statement 293
Cisco ONS 15454 Troubleshooting Guide, R8.5
2-82
In node view, double-click the receive ML-Series or CE-1000 card to open the card view.
Click the Provisioning > Card tabs.
In the Mode drop-down list, ensure that the same mode (GFP or HDLC) is selected. If it is not,
choose it and click Apply.
In node view, double-click the transmit ML-Series or CE-1000 card to open the card view.
Click the Provisioning > Card tabs.
In the Mode drop-down list, ensure that the same mode (GFP or HDLC) is selected. If it is not,
choose it and click Apply.
Encapsulation
CRC size
Scrambling state
Default Severity: Minor (MN), Non-Service-Affecting (NSA)
SONET Logical Object: OCN
DWDM Logical Object: TRUNK
Chapter 2
Alarm Troubleshooting
November 2009