Cisco ONS 15454 Troubleshooting Manual page 497

Hide thumbs Also See for ONS 15454:
Table of Contents

Advertisement

Chapter 4
Error Messages
Table 4-1
Error Messages (continued)
Error Warning
ID
Error Warning Message
EID-2102
The forced switch could not be removed for some circuits. You
must switch these circuits manually.
EID-2103
An error occurred while upgrading the span.
EID-2104
The circuits cannot be switched back because one or both nodes
are not reachable.
EID-2106
The node name cannot be empty.
EID-2107
An error occurred while adding {0}. The host is unknown.
EID-2108
{0} is already in the network.
EID-2109
The node is already in the current login group.
EID-2110
Please enter a number between 0 and {0}.
EID-2111
This node ID is already in use. Please choose another.
EID-2113
The extension byte for the ring cannot be set.
{0}
EID-2114
A card communication failure occurred during the operation.
EID-2115
An error occurred during the operation.
{0}
EID-2116
The extension byte setting for the ring is invalid.
{0}
EID-2118
The ring cannot be deleted.
A protection operation is set. All protection operations must be
clear for ring to be deleted.
EID-2119
{0} cannot be deleted because a protection switch is in effect.
Please clear any protection operations, ensure that the reversion
time is not "never" and allow any protection switches to clear
before trying again.
EID-2120
The following nodes could not be unprovisioned
{0}
Therefore you will need to delete this {1} again later.
EID-2121
The ring cannot be upgraded.
{0}
EID-2122
The ring speed for is inadequate for the upgrade procedure.
Only {0} (or higher) {1} can be upgraded to four-fiber.
November 2009
Description
The forced switch could not be removed for
some circuits. You must switch these
circuits manually.
There was an error during the span upgrade.
This error occurs during the path protection
span upgrade procedure.
You must supply a name for the node.
There was an error adding the specified
item.
The specified item exists in the network.
The node you are trying to add is already
present in the current login group.
You must enter a number in the range
between 0 and the specified value.
Select a node ID that is not in use.
CTC cannot set the BLSR/MS-SPRing
extension byte.
This error can occur during an attempt to
apply a BLSR protection operation to a line.
There was an error in applying the specified
operation.
The extension byte set for the specified ring
is invalid.
Clear all the protection operations for the
ring before deleting it.
Clear all protection operations or switches
before deleting the ring.
The specified nodes could not be
unprovisioned. Try deleting this BLSR or
MS-SPRing later.
CTC cannot upgrade the specified ring.
You have selected an incorrect ring speed
for upgrade. Only rings within the specified
parameters can be upgraded to 4-fiber
BLSR.
Cisco ONS 15454 Troubleshooting Guide, R8.5
4-9

Advertisement

Table of Contents
loading

Table of Contents