2.9.7 Interface Procedures
Replace the Alarm Interface Panel
Caution
Do not use a 2A AIP with a 5A fan-tray assembly; doing so causes a blown fuse on the AIP.
If any nodes in an Ethernet circuit are not using Software R4.0 or later, there is a risk of Ethernet traffic
Caution
disruptions. Contact Cisco TAC at 1 800 553-2447 when prompted to do so in the procedure.
Perform this procedure during a maintenance window. Resetting the active TCC2/TCC2P can cause a
Note
service disruption of less then 50 ms to OC-N or DS-N traffic. Resetting the active TCC2/TCC2P can
cause a service disruption of 3 to 5 minutes on all Ethernet traffic due to spanning tree reconvergence if
any nodes in the Ethernet circuit are not using Software R4.0 or later.
Do not perform this procedure on a node with live traffic. Hot-swapping the AIP can affect traffic and
Caution
result in a loss of data. For assistance with AIP replacement contact Cisco TAC 1 800 553-2447.
Always use the supplied electrostatic discharge wristband when working with a powered ONS 15454.
Caution
Plug the wristband cable into the ESD jack located on the lower-right edge of the shelf assembly.
This procedure replaces an existing AIP with a new AIP on an in-service node without affecting traffic.
Ethernet circuits that traverse nodes with a software release prior to R4.0 is affected.
You need a #2 Phillips screwdriver.
Step 1
Ensure that all nodes in the affected network are running the same software version before replacing the
AIP and repairing circuits:
a.
b.
Record the MAC address of the old AIP:
Step 2
a.
b.
c.
Call Cisco TAC 1 800 553-2447 for assistance in replacing the AIP and maintaining the original MAC
Step 3
address.
Step 4
Unscrew the five screws that hold the lower backplane cover in place.
Grip the lower backplane cover and gently pull it away from the backplane.
Step 5
Cisco ONS 15454 Troubleshooting Guide, R8.5
2-282
In network view, click the Maintenance > Software tabs. The working software version for each
node is listed in the Working Version column.
If you need to upgrade the software on a node, refer to the release-specific software upgrade
document for procedures. No hardware should be changed or circuit repair performed until after the
software upgrade is complete. If you do not need to upgrade software or have completed the software
upgrade, proceed to
Step
Log into the node where you are replacing the AIP. For login procedures, refer to the "Connect the
PC and Log into the GUI" chapter in the Cisco ONS 15454 Procedure Guide.
In node view, click the Provisioning > Network > General tabs.
Record the MAC address.
2.