Table 3-7
XTAL Factory-Selected Capacitor Selection
DVM
Reading (V)
Replace
15 with:
0 to 1.5
*
1.5 to 2.5
27
2.5 to 3.5
22
3.5 to 4.5
18
4.5 to 5.5
18
5.5 to 6.5
No change
6.5 to 7.5
No change
7.5 to 8.5
*
8.5 to 9.5
*
9.5 to 10
*
* Indicates a condition that should not exist; suspect broken hardware.
Table 3-8
Capacitor Part Numbers
Capacitor Value (pF)
6.8
8.2
10
12
15
18
20
22
24
27
Chapter 3
Currently Loaded Capacitor Value (pF)
Replace
Replace
18 with:
20 with:
*
*
*
*
27
27
22
24
20
22
No change
No change
No change
No change
15
18
15
15
*
15
Manual Adjustment Procedures
1. IF Bandpass Adjustment
Replace
Replace
22 with:
24 with:
*
*
*
*
*
*
27
27
24
27
No change
No change
No change
No change
18
22
18
20
18
20
Part Number
0160-4793
0160-4792
0160-4791
0160-4790
0160-4789
0160-4788
0160-5699
0160-4787
0160-5903
0160-4786
Replace
27 with:
*
*
*
*
*
No change
No change
24
24
24