13.Figure 9-22 on page 475
failures (slope error greater than 30 percent) and subtle 3 kHz
resolution bandwidth errors (less than 30 percent) indicate a
problem with A4U802, A4U803, A4U804, or A4U106.
14.Severe failure of the bandwidth accompanied by subtle errors in the
output signal indicate an A5 failure.
15.Set the 8566A/B controls as follows:
Center frequency ................................................ 10.710 MHz
Resolution bandwidth ................................................ 10 kHz
Video bandwidth ........................................................... 1 kHz
Sweep time .................................................................. 200 ms
16.On the 8564EC or 8565EC spectrum analyzer, press
. When the message IF ADJUST STATUS:1 kHz RBW
FULL IF ADJ
appears, press
SINGLE
17.Figure 9-23, "Output Waveform, 1 kHz Resolution Bandwidth"
illustrates normal operation. Severe failures (slope error greater
than 30 percent) and subtle 3 kHz resolution bandwidth errors (less
than 30 percent) indicate a problem with A4U802, U803, U804, or
U106.
18.On the 8564EC or 8565EC spectrum analyzer, press
. When the message IF ADJUST STATUS: 300 Hz RBW appears,
ADJ
press
on the 8566A/B.
SINGLE
19.Figure 9-24 on page 477
failures (slope error greater than 30 percent) and 3 kHz resolution
bandwidth errors (less than 30 percent) indicate a problem with
A4U802, U803, U804, or U106.
20.Reconnect W52 (white) to A4J8.
Chapter 9
Cal Oscillator (P/O A4 Assembly)
illustrates normal operation. Severe
on the 8566A/B.
illustrates normal operation. Severe
IF Section