Set The Media In Another Method - MIMAKI UJF-3042 MkII Series Operation Manual

Uv inkjet printer
Hide thumbs Also See for UJF-3042 MkII Series:
Table of Contents

Advertisement

Chapter 2 Basic Operation
Changing origin
The default origin position can be changed by pressing
JOG keys [][][][].
• The origin can also be changed from "ORIGIN
SETUP MENU". (
Changing with the JOG keys
Press the
1
in the local mode.
• The origin setting mode starts
• A red light pointer mark [] is projected on the
table or the media.
Move the light pointer mark by pressing
2
the
SET ORIGIN
X=    136.0  Y= -   60.0
TABLE HEIGHT
TABLE-DOWN
Origin Position
(back and front)
• Move the light pointer mark to the position to set a
new origin.
Press the
3
origin is determined.
• The origin is changed.
• The height of the table is also fixed at the same
time. Adjust the height of the table by pressing the
[FUNC1] key (down), the [FUNC3] key (up) in
advance.
• The setting value for the origin set with the JOG
keys is cleared by cutting the power.
• The setting of the table height holds even if turning
off the power.
2-6
P.3-5)
keys
keys.
53.0          
VACUUM
TABLE-UP
Origin Position
Origin Position
(height)
(right and left)
key when the printing

Set the media in another method

You can lower the table to set media more easily.
Press the
1
LOCAL mode.
• " WORK SET " will be displayed.
• The table moves down.
Set media along the L-shaped mark (print
2
origin) on the right corner of the table.
• To change the printing origin, see the following
page. (
P.2-6 "Changing origin")
• To use tools, set into the shaves (8.0 mm-deep)
on the corners of the table.
Press the
3
• The table moves up to the table height for
drawing.
About switching vacuum fan
The vacuum function to fix the media at printing
automatically starts. (Only for UJF-3042MkII EX/UJF-
3042MkII EX e, UJF-6042MkII/UJF-6042MkII e or when
using an absorption table.)
• You can set the vacuum function operation. For
details, refer to P.3-12 "Setting of FAN MODE."
• When you set the "Fan mode" of the setting mode
to "Manual", switch ON/OFF by pressing the [SEL]
and [FUNC1](VACCUM).
key in
(MENU)
key.