prompt, alarm upload, email will not be activated again. After 10s, if the system detects another
alarm signal, it can generate an alarm since the anti-dither time is out.
Alarm output: The number here is the device alarm output port. You can select the corresponding
ports(s) so the system can activate the corresponding alarm device(s) when an alarm occurrs.
Latch: When the anti-dither time ends, the channel alarm you select in the alarm output will last
the specified period. The value ranges from 1 to 300 seconds. This function is not for other alarm
activation operations. The latch is still valid even if you disable the alarm event function directly.
Show message: The system will show a pop up message on the local host screen when an alarm
occurs.
Alarm upload: The system wil upload the alarm signal to the network (including the alarm center
and the WEB) if you enabled this function. The system only uploads the alarm channel status.
You can go to the Alarm menu on the WEB interface to set an alarm event and alarm operation.
Please go to the Network interface to set the alarm center information.
Send email: An email will be sent out to alert you when an alarm occurs. Once you enable the
snap function, the system can also send out an image as an attachment. Please go to the Main
Menu->Setting->Network->Email interface to setup an email account.
Record channel: You can select proper channel to record the alarm video (Multiple choices).
You need to set alarm record mode as Schedule in the Record interface (Main
Menu->Advanced->Record). Please note manual record has the highest priority. If you
select Manual mode, the system will record all the time even if there is no alarm triggered.
Now you can go to the Schedule interface (Main Menu->Setting->Schedule) to set the record
type, corresponding channel number, week, and date. You can select the record type:
Regular/MD/Alarm/MD&Alarm. Please note, you can not select the MD&Alarm and MD (or
Alarm) at the same time.
Now you can go to the Encode interface to select alarm record and set the encode
parameter (Main Menu->Setting->Encode).
Finally, you can set the alarm input as the local alarm and then select the record channel.
The selected channel begins alarm recording when an alarm occurrs. Please note, the
system begins the alarm recording instead of the MD recording if the local alarm and MD
event occurr at the same time.
Tour: Here you can enable the tour function when an alarm occurs. The system supports
1/8-window tour. Please go to chapter 4.5.5 Display for the tour interval setup. Please note the
tour setup here has higher priority than the tour setup you set in the Display interf ace. Once the
two tours are both enabled, the system can enable the alarm tour when an alarm occurrs. If there
is no alarm, the system implements the tour setup in the Display interface.
Snapshot: You can enable this function to take a snapshot when an alarm occurs.
Buzzer: Highlight the icon to enable this function. The buzzer beeps when an alarm occurs.