Install - Siemens SINUMERIK 840D Operator's Manual

Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

Screen Kit: Software Update and Configuration (IK)
1 Software Installation
Possible exceptions/
problems during
SETUP:
1.2

INSTALL

Description
Availability of
components
IK/1-6
If a directory "<target drive>:\OP030" is found during setup, it is renamed
"<target drive>:\OP030.OLD" (after confirmation) or the setup procedure is
aborted.
If both OP030 and OP030.OLD already exist under "<target drive>", the
directories are not renamed. Please delete or rename those directories.
Important!
The maximum number of drives accessed must be set to (>L) in the
CONFIG.SYS file (e.g. LASTDRIVE=Z).
Install copies of your configuration settings, texts, configured user interface
and, where appropriate, your update software from the OP 030 update
software (from the OP 030 update directory on your PC) to your OP 030
hardware. It will be invoked automatically by SETUP but it may also be
executed at a later point in time.
You can select the following components for transmission:
– System Configuration Files
– Alarm Texts
– User Interface Languages
– Application Program
– System Software
The selection of one component means that the components listed before it
are also loaded on your OP 030. (This is necessary for reasons of data
integrity.)
The system configuration files are available with default entries and
INSTALL permits editing them if required.
The alarm texts are available with default entries (under
\OP030\proj\text\al\[LANGUAGE DIRECTORY]\*.txt).
*.txt files can be modified in standard editors; the modified files must be
converted into the internal OP 030 format (by using 'mkalarm', see next
section) before INSTALL is invoked.
The user interface texts are available in the internal OP 030 format for
English, French, German, Italian and Spanish.
INSTALL permits any two of these languages to be combined as foreground
and background languages.
The OP 030 application program and the OP 030 basic system software
are available as binary files.
SINUMERIK 840D/810D Configuring the OP 030 Operator Interface (FBO) – 09.01 Edition
(Settings for communication addresses
of partner)
(PLC user alarms)
(Two languages of your choice for the
user interface)
(proj.dat, the configured user interface)
(Complete base system of the OP 030)
© Siemens AG, 2001. All rights reserved
09.01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 810d

Table of Contents