SINUMERIK 840D/810D Configuring the Operator Interface OP 030 (FBO) – 09.01 Edition
5 Installation and Delivery of the Application Configuration
Connect the OP 030 to your PC on COM1 or COM2.
On the OP 030:
Switch on the power supply to the OP 030 or initiate a Power-ON-Reset.
The OP 030 runs up and for 5 seconds displays the initial screen with
the message that the self tests have been concluded and the menu for
further operator inputs.
Change to the update mode by entering the digit 6 on the OP 030
during those 5 seconds, if required.
Select a baud rate. (57.6KB is recommended.)
On your PC:
Exit Windows, because the transfer times are much shorter under DOS.
Change to the substitute drive L:\
Start the update process with
"install".
Follow the installation instructions for selecting a package, language
and PC COM Port.
Select the same baud rate on the PC as on the OP 030.
Development Kit (EU)