Spray Valve Switch (Multi Pro 1250 Only) - Toro Multi Pro 1200 Service Manual

Hide thumbs Also See for Multi Pro 1200:
Table of Contents

Advertisement

Spray Valve Switch (Multi Pro 1250 only)

The three (3) spray valve switches for the Multi Pro 1250
sprayers are located on the spray control console (Fig.
34). The switches are identical.
Testing
1. Park machine on a level surface, stop engine, en-
gage parking brake and remove key from ignition
switch.
2. Locate spray valve switch, remove console panel
and unplug machine wire harness connector from
switch.
3. The switch terminals are marked as shown in Figure
35. In the ON position, continuity should exist between
terminals 2 and 3 and also between terminals 5 and 6.
In the OFF position, continuity should exist between ter-
minals 1 and 2 and also between terminals 4 and 5.
4. Terminals 7 (--) and 8 (+) are used for the indicator
light in the switch. The light should be illuminated when
the switch is in the ON position.
5. Connect the harness connector to the switch after
testing. Install console panel to machine.
Multi Pro 1200/1250
2
1. Spray control console
2. LH spray valve switch
Page 5 - - 21
3
Figure 34
3. Center valve switch
4. RH spray valve switch
7
4
5
6
8
1
2
3
BACK OF SWITCH
Figure 35
Electrical System
4
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Multi pro 1250

Table of Contents