Toro Multi Pro 1200 Service Manual page 316

Hide thumbs Also See for Multi Pro 1200:
Table of Contents

Advertisement

Multi Pro 1250
Spray Circuit
Master Boom Switch ON
Pump Switch and All Spray Switches ON
Power Current
Control Current
Indicator/Gauge Current
BLACK
CLEAR
SHIELD
Page 10 - - 10
MASTER BOOM
SWITCH
D
A
RATE LOCKOUT
SWITCH
BLACK
CLEAR
SHIELD
NOTE: BOOM VALVES SHOWN AS OPENING AND
USING CURRENT. ONCE BOOM VALVES ARE
OPENED, A SWITCH IN THE BOOM VALVE WILL
SHUT OFF THE BOOM VALVE MOTOR. THE LIGHT
IN THE SPRAY SWITCH WILL STAY ILLUMINATED
AS LONG AS THE SWITCH IS IN THE ON POSITION.
REGULATING
VALVE
RIGHT BOOM
ACTUATOR
RELAY (LOWER)
RELAY (RAISE)
RELAY (LOWER)
RELAY (RAISE)
APPLICATION
RATE SWITCH
NOTE: WHEN THE PUMP SWITCH IS PRESSED
TO THE MOMENTARY ON POSITION, SWITCH
TERMINALS 5 AND 6 ARE USED TO INITIALLY
ENERGIZE THE PUMP RELAY AND ALSO TO CREATE
A LATCH CIRCUIT THROUGH SWITCH TERMINALS
2 AND 3. THIS LATCH CIRCUIT KEEPS THE PUMP
RELAY ENERGIZED AS SHOWN.
LEFT BOOM
ACTUATOR
(OPTIONAL KIT)
(ENERGIZED)
(ENERGIZED)

Advertisement