MASTER BOOM
SWITCH
BLACK
CLEAR
SHIELD
D
RATE LOCKOUT
SWITCH
BLACK
CLEAR
SHIELD
NOTE: LEFT BOOM VALVE CLOSING AND USING
CURRENT. ONCE LEFT BOOM VALVE IS CLOSED, A
SWITCH IN THE BOOM VALVE WILL SHUT OFF THE
BOOM VALVE MOTOR. THE LIGHT IN THE LEFT
SPRAY SWITCH WILL NOT BE ILLUMINATED.
REGULATING
VALVE
RELAY (LOWER)
RELAY (RAISE)
RELAY (LOWER)
RELAY (RAISE)
A
APPLICATION
RATE SWITCH
Multi Pro 1250
RIGHT BOOM
ACTUATOR
Spray Circuit
Master Boom Switch ON
Pump, Center Spray and Right Spray Switches ON
Left Spray Switch Turned To OFF
LEFT BOOM
ACTUATOR
NOTE: WHEN THE PUMP SWITCH IS PRESSED
TO THE MOMENTARY ON POSITION, SWITCH
TERMINALS 5 AND 6 ARE USED TO INITIALLY
ENERGIZE THE PUMP RELAY AND ALSO TO CREATE
A LATCH CIRCUIT THROUGH SWITCH TERMINALS
2 AND 3. THIS LATCH CIRCUIT KEEPS THE PUMP
RELAY ENERGIZED AS SHOWN.
Power Current
Control Current
Indicator/Gauge Current
(OPTIONAL KIT)
(ENERGIZED)
(ENERGIZED)