15.00 T-1 Carrier
Description
Programming
Conditions
The T-1 carrier is a hierarchy of digital systems designed to carry approx. 1.544
Mega bps. speech and other signals in digital form. The T-1 carrier has 24 PCM
(Pulse Code Modulation)voice channels.
T-1 trunk card (KX-T96187) and CSU(Channel Service Unit) are required to
utilize T-1 carrier with KX-TD500 System. This card supports five different trunk
interfaces to provide desired connection at minimum expense. One of the
following five trunk types can be assigned to one of 24 channels of T-1 card
individually according to tariffs and customer needs.
LCOT, GCOT, DID, OPX, TIE
System Programming
"Configuration — Slot Assignment"
"Configuration — DN Assignment"
"Configuration — Channel Assignment"
"System Clock Mode (CLK)"
"Master Clock Priority (CLP)"
"ESF Frame Option(EFO)"
1. Up to eight T-1 cards (192 ports) can be installed to the system under the
following conditions.
HLC+PLC+SLC+MSLC+ESLC+DLC+DHLC+
OPX+DID+LCOT+GCOT+RCOT+PCOT+
T-1+E-1
HLC+PLC+SLC+MSLC+ESLC+DLC+DHLC+
OPX+DID+LCOT+GCOT+RCOT+PCOT+
T-1+E-1
HLC+PLC+SLC+MSLC+ESLC+DLC+DHLC+
OPX+DID+LCOT+GCOT+RCOT+PCOT+
T-1+E-1
DID+LCOT+GCOT+RCOT+PCOT+T-1+E-1
T-1
E-1
Note:
• One T-1 card occupies 24 trunk ports.
• One E-1 card occupies 32 trunk ports.
3-F-89
Reference
VT
Dumb
10-C-2.00
11-C-2.00
10-C-3.00
11-C-3.00
10-C-4.00
11-C-56.01
—
11-C-56.02
—
11-C-56.03
—
11-C-56.04
512 ports/system
192 ports/basic shelf
224 ports/expansion shelf
192 ports/system
96 ports (4 cards)/shelf
128 ports (4 cards)/shelf