Panasonic KX-TD500 System Reference Manual page 221

Hide thumbs Also See for KX-TD500:
Table of Contents

Advertisement

1.01
Load Sharing
Description
Programming
Conditions
When two attendant consoles are equipped with the KX-TD500 system,
incoming calls directed to the attendant console are distributed to each
console evenly so that both consoles can share the same load.
1st
3rd
2nd
4th
Incoming call
In Dual Console Operation mode, "Load Sharing" is the default setting.
This setting can be changed to one of the following two settings by using
the WS3 command at Dumb programming mode.
• Simultaneous Ringing (Section 3-D-1.02)
• Interconsole IRNA (Section 3-D-1.03)
Refer to Section 11-C-45.00 "World Select 3 (WS3)" for further information.
System Programming
"Group-Trunk Group (1/3)",
Incoming Mode (Day)
"World Select 3 (WS3)",
1. General and Specific Calls
Incoming outside calls directed to the attendant console are categorized as
"General" or "Specific".
(General Calls)
• Operator Call (General)
• Incoming outside calls routed via CO lines which belong to a Trunk
Group whose Incoming Mode (Day) is "ATT".
• FDN for General Operator Call
(Specific Calls)
• Operator Calls (Specific)
• Directory Number for ATT1 and 2
2. Call Distribution Order
General calls are distributed to each console on the basis of "First In First
Out".
Specific calls always arrive at the specified attendant console.