Concluding Steps; Removing 2.5-Inch Hdd/Ssd Modules; Preliminary Steps - Fujitsu PRIMERGY RX1330 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX1330 M1:
Table of Contents

Advertisement

Hard disk drives / solid state drives
Figure 57: Installing the 2.5-inch HDD/SSD module
Ê Insert the HDD/SSD module into a drive bay and carefully push back as far
as it will go (1).
Ê Close the locking lever to lock the hard disk drive in place (2).
7.2.5.4

Concluding steps

"Performing a RAID array rebuild" on page 85
Ê
7.2.6

Removing 2.5-inch HDD/SSD modules

Customer Replaceable Unit
(CRU)
Tools: tool-less
7.2.6.1

Preliminary steps

Ê If the HDD/SSD module to be removed is combined into a RAID array,
please proceed as follows:
RAID level Procedure
Only remove an HDD module combined in a RAID 0 array if
defective.
RAID 0
122
V
CAUTION!
Removing an operational HDD module will result
in data loss!
Upgrade and Maintenance Manual
Hardware: 5 minutes
RX1330 M1