Hard disk drives / solid state drives
7.2.9

Replacing the 10 x 2.5-inch HDD backplane

Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver (for removing/installing SAS
expander board)
7.2.9.1

Preliminary steps

"Locating the defective server" on page 43
Ê
"Shutting down the server" on page 45
Ê
"Disconnecting the server from the mains" on page 46
Ê
"Getting access to the component" on page 47
Ê
Ê Release all HDD/SSD modules and pull them out a few centimeters, see
section
"Removing 2.5-inch HDD/SSD modules" on page 122
I
The HDD/SSD modules need not to be removed. But if you want to
remove them nevertheless, check if all HDD/SSD modules are
uniquely identified so that you can reinsert them into their original
bays.
7.2.9.2

Removing the SAS expander board

Figure 65: Disconnecting power cable from the HDD backplane
Ê Disconnect the power cable from the HDD backplane.
132
Upgrade and Maintenance Manual
Hardware: 15 minutes
RX1330 M1