6.3

Redundant power supply

Figure 26: PSU bays
6.3.1

Installing a hot-plug power supply unit

Customer Replaceable Unit
(CRU)
Tools: tool-less
6.3.1.1

Preliminary steps

No steps needed.
6.3.1.2

Removing the dummy cover

Figure 27: Removing a dummy cover
Ê Press in on both release latches (1) and remove the dummy cover (2).
V
CAUTION!
Keep the dummy cover for future use. If a power supply unit is removed
and not immediately replaced by a new one, a dummy cover must be
reinstalled in the bay to comply with applicable EMC regulations and
satisfy cooling requirements.
RX1330 M1
PSU 1
Upgrade and Maintenance Manual
PSU 2
Hardware: 5 minutes
Power supply
97