Front panel
13.2

Front panel module

13.2.1 Replacing the front panel module

Field Replaceable Unit
(FRU)
Tools: Phillips PH1 / (+) No. 1 screw driver
Note on system information backup / restore
I
The front panel contains the Chassis ID EPROM that contains system
information like server name and model, housing type, serial number and
manufacturing data.
To avoid the loss of non-default settings when replacing the system
board, a backup copy of important system configuration data is
automatically stored from the system board NVRAM to the Chassis ID
EPROM. After replacing the system board the backup data is restored
from the Chassis ID board to the new system board.
V
CAUTION!
For that reason the front panel and system board must not be replaced
simultaneously! In this case, restoring the system configuration data on
the system board would fail.

13.2.1.1 Preliminary steps

"Locating the defective server" on page 43
Ê
"Disabling SVOM boot watchdog functionality" on page 64
Ê
"Suspending BitLocker functionality" on page 63
Ê
"Shutting down the server" on page 45
Ê
"Disconnecting the server from the mains" on page 46
Ê
"Getting access to the component" on page 47
Ê
"Locating the defective component" on page 45
Ê