Fujitsu PRIMERGY RX1330 M1 Upgrade And Maintenance Manual page 311

Hide thumbs Also See for PRIMERGY RX1330 M1:
Table of Contents

Advertisement

Component
System board
CPU with CPU heat sink
1 memory module
Front panel module
Power supply unit
Table 5: Minimum startup configuration - components
Cable
Front panel cable
Power cable
Table 6: Minimum startup configuration - cables
"Shutting down the server" on page 45
Ê
"Disconnecting the server from the mains" on page 46
Ê
Ê Take the system down to its minimum startup configuration.
"Connecting the server to the mains" on page 55
Ê
Ê Connect a keyboard, mouse and display to the server.
Ê Switch on the server as described in section
page
57.
V
CAUTION!
Since the fan module is not included in the minimum startup
configuration, the server must be shut down immediately after the
diagnostic process is complete (POST phase has been passed).
The minimum startup configuration must be used exclusively for
diagnostic purposes by maintenance personnel, never in daily
operation!
RX1330 M1
Notes
no TPM, UFM or expansion cards installed
installed in DIMM slot 1A
Notes
Upgrade and Maintenance Manual
"Switching on the server" on
Appendix
311