Replacing A 3.5-Inch Hdd Module; Preliminary Steps - Fujitsu PRIMERGY RX1330 M1 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY RX1330 M1:
Table of Contents

Advertisement

Hard disk drives / solid state drives
7.3.4

Replacing a 3.5-inch HDD module

Customer Replaceable Unit
(CRU)
Tools: tool-less
V
CAUTION!
Only remove an HDD module during operation if the drive is not
currently being accessed. Observe the indicators on the HDD
module, see section
page
309.
Under no circumstances should you remove an HDD module while
the system is in operation if you are not sure that the drive is operated
by a RAID controller and belongs to a disk array that is operating in
RAID level 1, 1E, 10, 5, 50, 6 or 60.
An HDD module can only be replaced during operation in conjunction
with a corresponding RAID configuration.
All HDD modules (drives) must be uniquely identified so that they can
be reinstalled in their original bays later. If this is not done, existing
data can be lost.
7.3.4.1

Preliminary steps

"Locating the defective server" on page 43
Ê
"Locating the defective component" on page 45
Ê
Only applicable for removing intact HDD modules:
Ê Before removing a non-defective HDD module, put the drive into "Offline"
mode using your RAID configuration software.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
146
"Indicators on the hot-plug HDD module" on
Upgrade and Maintenance Manual
Hardware: 5 minutes
RX1330 M1

Advertisement