4
Command Line Interface
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure company
command interprets spaces as data input boundaries. The use of underscores
( _ ) or other unobtrusive non-letter characters is suggested for situations
where white space is necessary for clarity.
Example
Console(config)#banner configure company Samsung_Corporation
Console(config)#
banner configure dc-power-info
This command is use to configure DC power information displayed in the banner.
Use the no form to restore the default setting.
Syntax
banner configure dc-power-info floor floor-id row row-id rack rack-id
electrical-circuit ec-id
no banner configure dc-power-info [floor | row | rack | electrical-circuit]
• floor-id - The floor number.
• row-id - The row number.
• rack-id - The rack number.
• ec-id - The electrical circuit ID.
Maximum length of each parameter: 32 characters
Default Setting
None
Command Mode
Global Configuration
Command Usage
Input strings cannot contain spaces. The banner configure dc-power-info
command interprets spaces as data input boundaries. The use of underscores
( _ ) or other unobtrusive non-letter characters is suggested for situations
where white space is necessary for clarity.
Example
Console(config)#banner configure floor 3 row 15 rack 24
electrical-circuit 48v-id_3.15.24.2
Console(config)#