CLI – This example sets and displays the reauthentication time.
Console(config)#mac-authentication reauth-time 3000
Console(config)#network-access aging
Console(config)#exit
Console#show network-access interface ethernet 1/1
Global secure port information
Reauthentication Time
--------------------------------------------------
--------------------------------------------------
Port : 1/1
MAC Authentication
MAC Authentication Intrusion action
MAC Authentication Maximum MAC Counts : 1024
Maximum MAC Counts
Dynamic VLAN Assignment
Guest VLAN
Console#

Configuring MAC Authentication for Ports

Configures MAC authentication on switch ports, including setting the maximum MAC
count, applying a MAC address filter, and enabling dynamic VLAN assignment.
Command Attributes
• Mode – Enables MAC authentication on a port. (Default: None)
• Maximum MAC Count – Sets the maximum number of MAC addresses that can
be authenticated on a port. The maximum number of MAC addresses per port is
2048, and the maximum number of secure MAC addresses supported for the
switch system is 1024. When the limit is reached, all new MAC addresses are
treated as authentication failed. (Default: 2048; Range: 1 to 2048)
• Guest VLAN – Specifies the VLAN to be assigned to the port when MAC
Authentication or 802.1X Port Authentication fails. The VLAN must already be
created and active. (Default: Disabled; Range: 1 to 4094)
The VLAN must already be created and active (see "Creating VLANs" on page
3-193). Also, when used with 802.1X authentication, intrusion action must be set
for "Guest VLAN" (see "Configuring Port Settings for 802.1X" on page 3-90).
• Dynamic VLAN – Enables dynamic VLAN assignment for an authenticated port.
When enabled, any VLAN identifiers returned by the RADIUS server are applied to
the port, providing the VLANs have already been created on the switch. (GVRP is
not used to create the VLANs.) (Default: Enabled)
The VLAN settings specified by the first authenticated MAC address are
implemented for a port. Other authenticated MAC addresses on the port must have
the same VLAN configuration, or they are treated as authentication failures.
If dynamic VLAN assignment is enabled on a port and the RADIUS server returns
no VLAN configuration, the authentication is still treated as a success, and the host
assigned to the default untagged VLAN.
When the dynamic VLAN assignment status is changed on a port, all authenticated
addresses are cleared from the secure MAC address table.
3-104
: 3000
: Disabled
: Block traffic
: 2048
: Enabled
: Disabled