Displaying Current Vlans; Figure 3-108 Displaying Current Vlans - Samsung iES4028F Management Manual

Table of Contents

Advertisement

3
Configuring the Switch

Displaying Current VLANs

The VLAN Current Table shows the current port members of each VLAN and
whether or not the port supports VLAN tagging. Ports assigned to a large VLAN
group that crosses several switches should use VLAN tagging. However, if you just
want to create a small port-based VLAN for one or two switches, you can disable
tagging.
Command Attributes (Web)
• VLAN ID – ID of configured VLAN (1-4094).
• Up Time at Creation – Time this VLAN was created (i.e., System Up Time).
• Status – Shows how this VLAN was added to the switch.
- Dynamic GVRP: Automatically learned via GVRP.
- Permanent: Added as a static entry.
• Egress Ports – Shows all the VLAN port members.
• Untagged Ports – Shows the untagged VLAN port members.
Web – Click VLAN, 802.1Q VLAN, Current Table. Select any ID from the scroll-down
list.
Command Attributes (CLI)
• VLAN – ID of configured VLAN (1-4094, no leading zeroes).
• Type – Shows how this VLAN was added to the switch.
- Dynamic: Automatically learned via GVRP.
- Static: Added as a static entry.
3-192

Figure 3-108 Displaying Current VLANs