Iq8 Dark Streaks On Copied Image; Iq9 Copy Image Is Skewed - Xerox Phaser 8560MFP Service Documentation

Hide thumbs Also See for Phaser 8560MFP:
Table of Contents

Advertisement

IQ8 Dark Streaks on Copied Image

This RAP addresses image quality problems associated with the Scanner Assembly.
Initial Actions
1.
Check that supported media is being used.
2.
Reseat all cable connections between the Scanner Assembly and the Electronics Module.
3.
Check for Ink build-up or debris. Clean if necessary.
4.
Copy another page. If the problem persists, perform the following corrective actions.
Procedure
Table 1 IQ8 Dark Streaks on Copied Image
Step Questions and Actions
1
Check the CVT Window for ink build up.
Clean the CVT Window.
Scan another page.
Does the problem persist?
2
Check DADF calibration.
Perform the DADF to Scanner Calibration
adjustment procedure (ADJ 1.15.1).
Does the problem persist?
Initial Issue
Phaser 8510/8560MFP Multifunction Product
Yes
No
Go to Step 2.
Complete.
Replace the
Complete.
Scanner Assem-
bly (REP 1.0.11).
10/2006
3-7

IQ9 Copy Image is Skewed

This RAP addresses image quality problems associated with the Scanner Assembly.
Initial Actions
1.
Check that supported media is being used.
2.
Adjust the guides on the DADF Input Tray.
3.
Check that image skew exceeds specifications.
4.
Reseat all DADF connections.
Procedure
Table 1 IQ9 Copy Image is Skewed
Step Questions and Actions
1
Check that the original is printed on sup-
ported media and is undamaged.
Print the Paper Tips page for a listing of sup-
ported media.
Is the original supported?
2
Perform the DADF to Scanner Calibration
adjustment procedure (ADJ 1.15.1).
Does the problem persist?
Yes
No
Go to Step 2.
Use the Platen.
Replace the Scan-
Complete.
ner Assembly
(REP 1.0.11).
Image Quality
IQ8, IQ9

Hide quick links:

Advertisement

Table of Contents
loading