NOTE: Before replacing the Electronics Module for any POST errors, do the following:
1.
Unplug all wiring and/or cables to the Electronics Module.
2.
Plug in the AC power cable and power on the Electronics Module.
3.
If the error blink pattern is now different from the original error reported before Step 1, the
problem may not be in the Electronics Module. See Electrical Troubleshooting.
Table 2 POST Blink Pattern Error Reporting
Error
PS, PE, and Control
Error
Code
Panel LED s
Type Description
01.01 Flutter then 01 blinks
Hard Bad error code
02.01 Flutter then 02 blinks
Hard Failed machine check
02.02 Flutter then 02 blinks
Hard System panic
03.01 Flutter only
Soft
ID read failure
03.02 Flutter then 03 blinks
Hard Mismatch
03.03 Flutter only
Soft
Version mismatch
03.04 Flutter then 03 blinks
Hard Access failure
04.01 Flutter then 04 blinks
Hard ID read failure
04.02 Flutter then 04 blinks
Hard ID mismatch
04.03 Flutter then 04 blinks
Hard TMVL mismatch, read/write failed
04.04 Flutter then 04 blinks
Hard TMVL mismatch, read/write failed
05.01 Flutter then 05 blinks
Hard I/O Board serial communication error.
05.02 Flutter only
Soft
I/O Board serial mismatch error.
6.08
No indication
Soft
Hard Drive failure
07.01 Flutter only
Soft
Control Panel communications error
07.02 Flutter only
Soft
Control Panel version mismatch
08.01 Flutter only
Soft
Control Panel failed to initialize
09.01 Flutter only
Soft
Control Panel data error
10.01 Flutter then 10 blinks
Hard Power control link failure
10.02 Flutter only
Soft
Power control link invalid, mismatch error
11.01 Flutter then 11 blinks
Hard EEPROM read failure
11.02 Flutter then 11 blinks
Hard EEPROM write failure
11.03 Flutter then 11 blinks
Hard EEPROM re-read failure
11.04 Flutter then 11 blinks
Hard EEPROM data failure
12.nn Flutter only
Soft
Configuration Card failure
13.01 Flutter then 13 blinks
Hard PHY reset failure (Low)
13.02 Flutter then 13 blinks
Hard PHY ID error
14.nn Flutter then 14 blinks
Hard USB ASIC error
15.01 Flutter then 15 blinks
Hard CPU interrupt error
15.02 Flutter then 15 blinks
Hard CPU interrupt error
15.03 Flutter then 15 blinks
Hard CPU interrupt error, IRQ
15.04 Flutter then 15 blinks
Hard CPU interrupt error
15.05 Flutter then 15 blinks
Hard CPU interrupt error
15.06 Flutter then 15 blinks
Hard CPU interrupt error
Error Messages and Codes
Power On Self Tests
Table 2 POST Blink Pattern Error Reporting
Error
PS, PE, and Control
Error
Code
Panel LED s
Type Description
15.07 Flutter then 15 blinks
Hard CPU interrupt error
15.08 Flutter then 15 blinks
Hard CPU interrupt error
15.09 Flutter then 15 blinks
Hard CPU interrupt error
15.10 Flutter then 15 blinks
Hard CPU interrupt error
15.11 Flutter then 15 blinks
Hard CPU interrupt error
16.01 Flutter only
Soft
16.02 Flutter only
Soft
16.03 Flutter only
Soft
16.04 Flutter only
Soft
17.01 Flutter then 17 blinks
Hard Insufficient RAM memory
18.01 Flutter then 18 blinks
Hard IPCB ID read failure
18.02 Flutter then 18 blinks
Hard IPCB ID mismatch
18.03 Flutter then 18 blinks
Hard IPCB PCI configuration failure
18.04 Flutter only
Soft
19.01 Flutter then 19 blinks
Hard Hard Drive failure
PEST Error Reporting
PEST tests occur after POST tests have been run and PostScript has been initialized. PEST
checks the connections and operation of various system components.
Error codes for PEST tests are displayed on the Control Panel and are all in the 37,XXX.xx
series. For troubleshooting PEST error codes, see Error Message Troubleshooting.
10/2006
2-4
Real Time Clock read failure
Real Time Clock write failure
Real Time Clock re-read failure
Real Time Clock failure
IPCB version mismatch