Xerox Phaser 8560MFP Service Documentation page 212

Hide thumbs Also See for Phaser 8560MFP:
Table of Contents

Advertisement

Table 3 Service Diagnostics Menu Definitions
Menu Item
Description
Scanner Menu
Report FW Version
Reports current firmware version.
Report Status
Reports the current Scanner Assembly status:
OK- (no errors detected)
Internal Target Failure
Optical Test Error
Home Position Test Error
Check Lock Test Error
Report Lamp Status
The Scanner reports the current lamp status as On, Off, or Warming
Up. The Warming Up status includes the dim state, which won't
change to On until instructed to do so.
Monitor Sensors
This monitors the state of the Scanner Cover (DADF or Document
Cover) Sensor. Toggle the sensor state by opening the cover.
Exercise DRAM
The Scanner performs a DRAM test. Errors are reported as a Internal
Target Failure and the lamp flashes twice.
Exercise Axis Motion The Scanner moves the scan axis to the Home position, then to the
right limit of travel, and then back to the Home position. This test exer-
cises the axis motion mechanism and the Home sensor.
Exercise Axis
The Scanner performs a Locked test. Errors are reported as Check
Unlocked
Lock Test Error. The test determines if the scanner motion axis is cur-
rently unlocked and available for use.
Exercise Data Cap-
The Scanner performs a Data Capture test which exercises the lamp,
ture
optics, CCD, DRAM, and supporting electronics. Errors are reported
as an Optical Device Error. For this test the lamp is on and the scan
head is moved under the calibration strip.
Exercise Lamp
The Scanner turns the lamp On, Off, then On. Each state is held for a
short time to allow observation of the lamp state. Errors with a light
state transition are reported as a Light Check Error. The lamp may be
On prior to the test, and the lamp is left On after the test. Each lamp
On transition triggers a calibration function which takes approximately
50 seconds to complete. The test exercises the lamp and the lamp
control.
Test Scanner Sub-
The Scanner runs a series of tests to verify the operation of these
system
Scanner functions as previously described:
DRAM
Unlock
Motion
Capture
Lamp
Reset Scanner Sub-
This test forces a hardware reset of the Exit Module, Scanner, DADF
system
and FAX modules.
Diagnostics
Service Diagnostics
Table 3 Service Diagnostics Menu Definitions
Menu Item
Description
Doc Handler Menu
Report FW Version
Reports the current DADF firmware version.
Report Status
Reports the current DADF module status:
OK - (no errors detected)
Paper Jam
Cover Open
Internal Target Failure
Test Fail
Optical Test Error
Calibration Device Error
Report Lamp Status
The DADF reports the current lamp status as On, Off, or Warming Up.
The Warming Up status includes the dim state, which won't change to
On until instructed to do so.
Report Paper Status
The DADF reports the current status as Paper or No Paper.
Monitor Sensors
Tests the DADF No Paper and Cover Sensors. Toggle the actuator to
change sensor state. Results are reported as Paper Present or Not
Present, and Cover Open or Closed.
Exercise DRAM
The DADF performs a DRAM test. Errors are reported as a Internal
Target Failure and the lamp flashes twice.
Exercise Data Cap-
The DADF performs a Data Capture test which exercises the lamp,
ture
optics, CCD, DRAM, and supporting electronics. Errors are reported
as an Optical Device Error. For this test the lamp is on and the scan
head is moved under the calibration strip.
Test Cal Sheet Motion The DADF performs a Calibration Motion test which moves the cal
sheet out under the lamp. Errors are reported as a Calibration Device
Error. The test determines if the cal sheet motion is as expected.
Exercise Feed Motion The DADH performs a Transmission test. This test rotates the trans-
port rollers for a short time (sufficient to transport a 14 inch sheet of
paper). The test requires observation of the correct action, and a final
status of Complete is always reported. Remove all media from the
DADF before running this test.
Exercise Lamp
The DADF turns the lamp On, Off, then On. Each state is held for a
short time to allow observation of the lamp state. Errors with a light
state transition are reported as a Light Check Error. The lamp may be
On prior to the test, and the lamp is left On after the test. Each lamp
On transition triggers a calibration function which takes approximately
50 seconds to complete. The test exercises the lamp and the lamp
control.
10/2006
6-10
Initial Issue
Phaser 8510/8560MFP Multifunction Product

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents