28.5.5

Adjustment of horizontal position

Note:
Check if the image adjustment for the equipment is performed properly before this adjustment of
the RADF. Also, the RADF position and height shall be adjusted properly.
[A] Checking
Check the image using the chart (original) with a center line in the following procedure.
(1)
Place the chart provided as an original with its face up on the original tray of the RADF.
(2)
Press the [START] button.
(3)
Fold the copy in half and check if the center line is misaligned.
[B] Adjustment
(1)
Turn the power ON while pressing [0] and [5] simultaneously.
(2)
Key in [358] and then press the [START] button.
If the center line of the copy image is shifted to the front side of the equipment, enter a value
larger than the current one.
Note:
Changing one value shifts the copy image by 0.0423 mm.
If the center line of the copy image is shifted to the rear side of the equipment, enter a value
smaller than the current one.
Note:
Changing one value shifts the copy image by 0.0423 mm.
(3)
Press the [ENTER] button.