26.5.8

Poor fusing

Cause/Section
Step
Electric power/
1
Is the connector in proper contact with the
control abnormal
equipment?
2
Is the heater lamp control circuit
(switching power supply) working
properly?
3
Are the connectors on the LGC board and
joint connectors connected properly?
4
Is the LGC board normal?
5
Is the harness connected with the LGC
board short circuited or open circuited?
Pressure
6
Are the pressure springs working
between fuser
properly?
belt and
pressure roller
improper
Fuser roller
7
Is the temperature of fuser roller too low?
temperature
Developer
8
Using the specified developer material
material and
and toner?
toner
Paper
9
Is the paper damp?
10
Is the paper type corresponding to its
mode?
11
Using the recommended paper?
© 2008, 2009 TOSHIBA TEC CORPORATION All rights reserved
Fig. 26-7
Check items
26 - 133
Measures
Correct it.
Replace the switching power supply.
Reconnect them.
Replace the LGC board.
Replace the harness.
Check/adjust the pressure springs.
Check/correct the setting value of fuser
roller temperature.
Clean or replace the thermopiles.
Check/correct the related circuit.
Use the specified developer material and
toner.
Change the paper.
Use the proper type of paper or select the
proper mode.
Use the recommended paper.