Toshiba Tecra 700CS Maintenance Manual page 28

700 series
Hide thumbs Also See for Tecra 700CS:
Table of Contents

Advertisement

Check 2
If error code 01h displays:
Make sure the AC adapter's cable and AC cord are firmly plugged into the
DC IN 15 V socket and wall outlet. If these cables are connected
correctly, go to the following step.
Connect a new AC adapter.
If the error still exists, go to Procedure 5.
Check 3
If error code 02h displays:
Make sure the Desk Station V is firmly connected to the computer's
expansion bus port. If this port is connected correctly, go to the following
step.
Replace the Desk Station V with a new one.
If the error still exists, go to Procedure 5.
Check 4
If error code 10h displays:
Make sure the battery pack is correctly installed in the computer.
If the battery pack is correctly installed, go to the following step.
Replace the battery pack with a new one.
If the error still exists, go to Procedure 5.
Check 5
When 80h is displayed, it indicates that the CPU temperature is outside the allow-
able operating range. Perform the following steps.
Leave the computer in an area that is about room temperature until the
CPU's internal temperature is within the allowable operating range.
If the error still exists, go to Procedure 5.
Check 6
For any other error, go to Procedure 5.