Battery pack
Error code
10h
11h
12h
13h
B5V, VCC power supply output
Error code
20h
21h
22h
23h
24h
B3V output
Error code
30h
31h
32h
33h
P12V Output
Error code
40h
41h
42h
Power supply microcontroller
Error code
50h
Environmental condition
Error code
80h
700 Series
Meaning
Battery voltage is over the maximum allowed limit.
Battery charge current is over the maximum allowed limit.
Battery discharge current is over the maximum allowed limit when
there is no load.
Battery charge current is over the maximum allowed limit.
Meaning
B5V voltage is over the maximum allowed limit.
B5V voltage is below the minimum allowed limit.
B5V or VCC does not start up when the power supply is turned on.
VCC voltage is below the minimum allowed limit.
During suspend, B5V voltage is below the minimum allowed limit.
Meaning
B3V Voltage is over the maximum allowed limit.
B3V Voltage is below the minimum allowed limit.
B3V does not start when the power supply is turned on.
B3V is below the minimum allowed limit during suspend.
Meaning
P12V Voltage is over the maximum allowed limit.
P12V Voltage is below the minimum allowed limit.
P12V does not start when the power supply is turned on.
Meaning
Firmware or program error.
Meaning
CPU temperature is outside the allowable range.