11.6 Disassembly and Replacement

[A]
Cleaner unit
(1)
Take off the main charger.
(
P.10-9 "[A] Main charger")
(2)
Disconnect 1 connector and remove 2
screws to pull out the cleaner unit.
[B]
Drum thermistor (THM5) and Drum
(1)
Take off the cleaner unit
(
P.11-7 "[A] Cleaner unit")
(2)
Disconnect 1 connector and remove 1 screw
to take off the drum thermistor with its
bracket.
(3)
Remove 1 screw to take off the drum ther-
mistor.
Note:
When installing the thermistor, tighten it with
the 0.2-0.6N•m torque.
(4)
Turn the cam to release the pressure of the
cleaning blade.
(5)
Remove 3 screws to take off the drum shaft.
March 2005 © TOSHIBA TEC
Screw
Cleaner unit
Fig.11-6
Connector
Screw
Drum thermistor
Fig.11-7
Cam
Fig.11-8
e-STUDIO520/600/720/850 DRUM/CLEANER UNIT
11 - 7
Screw
Main charger
Drum shaft
11