[E-5]
Large original exit motor (M39)
(1)
Take off the ADF board with its bracket
(
P.16-87 "[C] RADF control PC board
(ADF board)").
(2)
Disconnect 1 connector and remove 1
spring.
(3)
Loosen 2 screws to release the tension of
the belt. Then tighten these screws tempo-
rarily.
(4)
Remove 2 screws to take off the large origi-
nal exit motor with its bracket.
(5)
Remove 2 screws to take off the large origi-
nal exit motor from the bracket.
<Installation procedure>
(6)
Hang the timing belt over the pulley of the
large original exit motor. Then fix the bracket
with 2 screws.
(7)
Attach 1 spring.
(8)
Loosen the screws fixing the bracket tempo-
rarily. Then tighten these screws so that the
timing belt will be tightened.
Note:
Be sure that the timing belt has been tight-
ened completely.
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
Connector
16 - 92
Tension spring
Fig.16-125
Screw
Screw
Fig.16-126
Large original exit motor
Fig.16-127