[G-5]
Original tray sensor (S53) / Original tray width sensor (S54)
(1)
Lift up the tray and remove 3 screws to take
off the tray back cover.
(2)
Disconnect 1 connector to take off the origi-
nal tray sensor.
(3)
Disconnect 1 connector and remove 1 screw.
Then take of the original tray width sensor
with its stay.
(4)
Remove the nut to take off the original tray
width sensor from its stay.
Note:
When the original tray width sensor is
installed, install it to match the markings on
the rack and pinion each other.
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
Tray back cover
Original tray sensor
16 - 96
Fig.16-137
Connector
Fig.16-138
Screw
Connector
Original tray width sensor
Fig.16-139
March 2005 © TOSHIBA TEC