(7)
Disconnect 1 connector to take off the fuser
transport sensor.
[L]
Pressure roller thermistor (THM4)
(1)
Take off the fuser unit
(
P.14-18 "[B] Fuser unit").
(2)
Disconnect 1 connector of the pressure roller
thermistor.
(3)
Remove 2 screws to take off the lower
entrance guide.
(4)
Remove 1 screw to take off the harness
cover.
(5)
Remove 1 screw to take off the pressure
roller thermistor.
Notes:
1. Use tightening torques of 0.4-0.6 N
prevent the thermistors from damage.
2. Be sure that the thermistor is contacting
with the pressure roller when it has been
installed.
e-STUDIO520/600/720/850 FUSER UNIT
Pressure roller thermistor
Harness cover
·
m to
14 - 30
Fuser transport sensor
Fig.14-45
Fig.14-46