(5)
Disconnect 1 connector to take off the origi-
nal intermediate transport sensor.
[G-8]
RADF opening/closing switch (SW9)
(1)
Take off the ADF rear cover
(
P.16-86 "[B-2] ADF rear cover").
(2)
Disconnect 3 connectors.
(3)
Remove 1 screw to take off the RADF open-
ing/closing switch with its bracket.
(4)
Remove 1 screw to take off the RADF open-
ing/closing switch from its bracket.
Note:
Connect 3 connectors to the switch in the
arrangement shown in the figure.
[G-9]
Large original exit sensor (S68)
(1)
Open the jam access cover.
(2)
Open the reverse guide. Then release the
inserted portion on the front side to take out
the guide to the front side.
(3)
Open the scanning guide. Then take it out
upward by holding its both ends.
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
Original intermediate transport sensor
Small original transport guide
RADF opening/closing switch
Scanning guide
16 - 98
Fig.16-143
Blue Orange Brown
Screw
Fig.16-144
Fig.16-145