[C-2]
Bypass feed clutch (CLT4)
(1)
Disconnect the connector and then remove
the harness band and clip to take off the
bypass feed clutch.
Note:
When assembling, be sure that the stopper
of the clutch is securely inserted into the
groove of the bracket.
[C-3]
Bypass pickup solenoid (SOL3) / Bypass feed sensor (S27)
(1)
Remove 5 screws, disconnect 2 connectors
and take off the stay.
(2)
Disconnect the connector and take off the
bypass feed sensor.
March 2005 © TOSHIBA TEC
Connector
Harness band
Fig.9-38
Connector
Screw
Screw
Fig.9-39
Bypass feed sensor
Stay
Fig.9-40
e-STUDIO520/600/720/850 PAPER FEEDING SYSTEM
9 - 29
Clip
Bypass feed clutch
Stay
Screw
Connector
9