[G-13] Small original exit sensor (S67) / Small original reverse sensor (S66)
(1)
Take off the ADF right cover
(
P.16-86 "[B-4] ADF right cover").
(2)
Remove 2 screws to take off the sensors
with its bracket.
(3)
Disconnect 1 connector to take off the small
original exit sensor.
(4)
Remove 1 screw to take off the sensor plate.
(5)
Remove 1 screw to take off the small original
reverse sensor.
[H] Platen guide
(1)
Remove 2 screws fixing the platen guide.
(2)
Move the guide to the direction of the arrow
in the figure so that the right edge of the
guide can be seen.
(3)
When its right edge is seen, take out the
platen guide in the direction of the arrow in
the figure.
March 2005 © TOSHIBA TEC
Small original reverse sensor
Screw
Platen guide
Screw
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
16 - 101
Bracket
Fig.16-152
Small original exit sensor
Fig.16-153
Fig.16-154