[F]
Solenoid
[F-1]
Small original exit solenoid (SOL4)
(1)
Take off the large original exit motor
(
P.16-92 "[E-5] Large original exit motor
(M39)").
(2)
Disconnect 1 connector.
(3)
Release the latch. Then remove the arm and
plunger.
(4)
Remove 1 screw to take off the small original
exit solenoid with its bracket.
(5)
Remove 2 screws to take off the small origi-
nal exit solenoid from its bracket.
[F-2]
Large original exit solenoid (SOL5)
(1)
Take off the ADF rear cover
(
P.16-86 "[B-2] ADF rear cover").
Note:
The jam access cover should be opened.
(2)
Disconnect 1 connector to release the har-
ness from the harness duct.
(3)
Remove 1 screw to take off the large original
exit solenoid with its bracket.
(4)
Remove 1 screw to take off the large original
exit solenoid from its bracket.
[F-3]
Large original exit roller release solenoid (SOL6)
(1)
Take off the ADF rear cover
(
P.16-86 "[B-2] ADF rear cover").
Then close the jam access cover.
(2)
Remove the clip to take off the release sole-
noid linkage.
(3)
Disconnect 2 connectors.
(4)
Remove 1 screw, release 2 latches and take
off the harness duct.
(5)
Remove 1 screw to take off the large original
exit roller release solenoid with its bracket.
(6)
Remove 2 screws to take off the large origi-
nal exit roller release solenoid from its
bracket.
March 2005 © TOSHIBA TEC
Small original exit solenoid
Screw
Large original
exit solenoid
Release solenoid
linkage
Large original exit roller
release solenoid
e-STUDIO520/600/720/850 REVERSING AUTOMATIC DOCUMENT FEEDER (RADF)
16 - 93
Screw
Fig.16-128
Harness duct
Connector
Fig.16-129
Clip
Harness duct
Connector
Screw
Screw
Fig.16-130
16