Toshiba e-STUDIO520 Service Manual page 267

Multifunctional digital systems
Hide thumbs Also See for e-STUDIO520:
Table of Contents

Advertisement

[E]
Doctor blade
(1)
Take out the developer material.
(
P.12-19 "[D] Developer material")
(2)
Remove 2 screws and take off the doctor
blade.
Note:
When installing the doctor blade, butt both
edges to the protrusion on the front and rear
side frame and tighten the screw. (The doc-
tor sleeve gap does not need to be adjusted.)
[F]
Auto-toner sensor (S12)
(1)
Take out the developer material.
(
P.12-19 "[D] Developer material")
(2)
Release the harness from the clamp and pull
out the harness.
(3)
Remove 2 screws to take off the auto-toner
sensor.
March 2005 © TOSHIBA TEC
Doctor blade
Screw
Fig.12-27
Doctor blade
Fig.12-28
Auto-toner sensor
Fig.12-29
e-STUDIO520/600/720/850 DEVELOPER UNIT
12 - 21
Screw
Protrusion